Can You Add a Sensor or a Second Filling Unit to an Existing Machine?
Review PLC capacity, signal compatibility, product supply and software before adding detection or a second filling head to an existing machine.
An existing machine may accept another sensor, an additional control step or a second filling unit if its mechanical and control systems are suitable. Empty cabinet space is not enough. PLC I/O, electrical infrastructure, product supply, conveyor layout and program access all need assessment.
A sensor for missing-bottle detection and a second head for output or product flexibility are different projects with different tests.
What matters when adding a sensor?
Material, colour, transparency, distance and movement affect detection. An ordinary object sensor should not be assumed to detect every clear bottle. Test the actual container in relevant empty and filled conditions.
Available PLC inputs are only part of the check. Signal type, electrical compatibility, supply and response needs matter too. Connections are planned from actual device drawings with qualified electrical personnel, not from wire colour alone.
Is an illuminated sensor LED enough?
No. The PLC must receive the correct signal and use it at the correct step. Define what happens if detection fails, remains permanently on or arrives late. The machine needs an agreed response, not just a new input.
Send machine footage, PLC/module labels and the function you want to add. We can assess the hardware and software scope together.
Let’s talk about your machine
If you’d like to talk, leave your name and phone number and we’ll give you a call.
Thank you. We’ll be in touch.
Will a second head double output?
Not automatically. Supply, pump capacity, shared product paths, bottle spacing and delays elsewhere in the cycle all affect output. Two nozzles do not guarantee equal product supply or equal quantities.
AreaQuestionMechanicsIs there space and suitable bottle positioning?SupplyCan both units receive stable product flow?PLC and cabinetAre suitable I/O and control components available?SoftwareHow are dosing, faults and the new sequence coordinated?OperatorAre settings, alarms and cleaning steps clear?
What if the old source project is missing?
Review editable backups and access before promising a small modification. Even a sensor can need program changes. If a usable project cannot be recovered, rewriting software or another control approach may be required.
Why must testing and protective functions be reviewed?
Additional equipment can affect movement and operator access. A suitable team must assess guards, stopping and restart behaviour. The agreed tests may include normal operation, missing bottles, sensor faults, loss of product supply and quantity checks for each head.
What should you send for a quotation?
Provide a short video, cabinet and PLC photographs, electrical drawings if available, target output and a description of the change. If bottles are detected but filling does not start, diagnosing the existing fault may be preferable to buying more hardware.
Manufacturer reference
Omron E3ZM-B transparent-object detection illustrates application-specific sensor selection; it does not mean this model is installed on all our machines.
Discuss your product or machine with us
Başakşehir Makine is based at İkitelli OSB, Atatürk Blv. Beyaz Tower, Floor 6, No. 90, Başakşehir, Istanbul, Turkey. We agree the scope of on-site work in Istanbul and, for suitable PLC projects across Turkey, remote support or shipment of the controller. For machinery enquiries, samples, delivery and commissioning are agreed in the quotation.